Files

231 lines
5.1 KiB
Markdown

# Nivetti NiOS MIBs
The following minimum parameters are required to be discovered to retrieve data using SNMP from Nivetti make Routers, in order to monitor them through a Network Management System (NMS).
---
## Required Minimum Parameters for SNMP Discovery
Standard SYSTEM-MIB is supported
(Details to be configured in System PG)
### System Information
1. System Name
2. System Description
3. System Uptime
4. System Contact
5. System Location
---
## CPU Utilization
1. Current CPU Utilization
OID: .1.3.6.1.4.1.46634.1.2.5.1.1.1.5.1.3.0.1
CPU usage is displayed in tenths of a percent unit.
To get absolute percentage, divide the fetched value by 10.
2. Average CPU Utilization (1 min / 5 min / 15 min)
Currently Not Available
3. Per-Core Utilization
Per-core utilization is not applicable for this device
---
## Memory Utilization
### RAM
- Total Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.1
- Used Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.1
- Free Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.1
- Memory Utilization (%)
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.1
---
### Internal Storage (Flash)
- Total Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.2
- Used Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.2
- Free Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.2
- Memory Utilization (%)
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.2
---
### User Storage (Flash)
- Total Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.3
- Used Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.3
- Free Memory
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.3
- Memory Utilization (%)
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.3
---
## Interface Statistics
Standard IF-MIB is supported for both physical and virtual interfaces.
- Interface Name / Description
- Interface Type (Ethernet, Serial, Loopback, etc.)
- Interface Duplex Status
- Interface Status (Up / Down)
- Operational Status (Up / Down)
- Administrative Status (Up / Down)
- Interface IP Address
- Interface Subnet Mask
- Interface Index
- Interface Speed
- Inbound Octets
- Outbound Octets
- Inbound Unicast Packets
- Outbound Unicast Packets
- Inbound Discards
- Outbound Discards
- Inbound Errors
- Outbound Errors
- Input Queue Length
- Output Queue Length
---
## Temperature Sensors
Private MIB / OID
### Current Temperature Readings
- Air Inlet Temperature
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.1
- Air Outlet Temperature
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.2
- CPU Temperature
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.3
### Low Tolerance Thresholds
- Low Air Inlet Tolerance
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.1
- Low Air Outlet Tolerance
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.2
- Low CPU Tolerance
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.3
### High Tolerance Thresholds
- High Air Inlet Tolerance
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.1
- High Air Outlet Tolerance
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.2
- High CPU Tolerance
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.3
---
## Power Supply Status
Use: NIOS-CHASSIS-MIB
Displayed only when the power module is ON
### Power Module A
- State
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.4.1.992.0
- Failure Reason
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.5.1.992.0
- Input Voltage
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.6.1.992.0
- Output Voltage
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.7.1.992.0
- Input Current
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.8.1.992.0
- Output Current
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.9.1.992.0
### Power Module B
- State
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.4.1.993.0
- Failure Reason
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.5.1.993.0
- Input Voltage
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.6.1.993.0
- Output Voltage
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.7.1.993.0
- Input Current
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.8.1.993.0
- Output Current
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.9.1.993.0
---
## Fan Status
Private MIB / OID
### Fan 1
- State (RPM)
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.1
- Speed (RPM)
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.1
### Fan 2
- State
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.2
- Speed (RPM)
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.2
### Fan 3
- State
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.3
- Speed (RPM)
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.3
---
## Routing Table Information (Summary)
- Number of active routes
- Number of OSPF / BGP neighbors
Currently Not Available
Please share the OIDs being used in the EMS for other devices in the network.
---
## Session Information (NAT)
- Number of active NAT sessions
Additional details required.
Please share the OIDs currently used in the EMS for other devices.
---
## SLA Monitoring Parameters
Additional details required.
Please share the OIDs currently used in the EMS for other devices.
- End-to-End Latency (e.g., ICMP RTT)
- Jitter
- Packet Loss
- SLA Operation Status (Active / Failed)
- SLA Threshold Breach Status