Files

5.1 KiB

Nivetti NiOS MIBs

The following minimum parameters are required to be discovered to retrieve data using SNMP from Nivetti make Routers, in order to monitor them through a Network Management System (NMS).


Required Minimum Parameters for SNMP Discovery

Standard SYSTEM-MIB is supported
(Details to be configured in System PG)

System Information

  1. System Name
  2. System Description
  3. System Uptime
  4. System Contact
  5. System Location

CPU Utilization

  1. Current CPU Utilization
    OID: .1.3.6.1.4.1.46634.1.2.5.1.1.1.5.1.3.0.1
    CPU usage is displayed in tenths of a percent unit.
    To get absolute percentage, divide the fetched value by 10.

  2. Average CPU Utilization (1 min / 5 min / 15 min)
    Currently Not Available

  3. Per-Core Utilization
    Per-core utilization is not applicable for this device


Memory Utilization

RAM

  • Total Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.1
  • Used Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.1
  • Free Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.1
  • Memory Utilization (%)
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.1

Internal Storage (Flash)

  • Total Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.2
  • Used Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.2
  • Free Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.2
  • Memory Utilization (%)
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.2

User Storage (Flash)

  • Total Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.3
  • Used Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.3
  • Free Memory
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.3
  • Memory Utilization (%)
    OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.3

Interface Statistics

Standard IF-MIB is supported for both physical and virtual interfaces.

  • Interface Name / Description
  • Interface Type (Ethernet, Serial, Loopback, etc.)
  • Interface Duplex Status
  • Interface Status (Up / Down)
  • Operational Status (Up / Down)
  • Administrative Status (Up / Down)
  • Interface IP Address
  • Interface Subnet Mask
  • Interface Index
  • Interface Speed
  • Inbound Octets
  • Outbound Octets
  • Inbound Unicast Packets
  • Outbound Unicast Packets
  • Inbound Discards
  • Outbound Discards
  • Inbound Errors
  • Outbound Errors
  • Input Queue Length
  • Output Queue Length

Temperature Sensors

Private MIB / OID

Current Temperature Readings

  • Air Inlet Temperature
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.1
  • Air Outlet Temperature
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.2
  • CPU Temperature
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.3

Low Tolerance Thresholds

  • Low Air Inlet Tolerance
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.1
  • Low Air Outlet Tolerance
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.2
  • Low CPU Tolerance
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.3

High Tolerance Thresholds

  • High Air Inlet Tolerance
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.1
  • High Air Outlet Tolerance
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.2
  • High CPU Tolerance
    OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.3

Power Supply Status

Use: NIOS-CHASSIS-MIB
Displayed only when the power module is ON

Power Module A

  • State
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.4.1.992.0
  • Failure Reason
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.5.1.992.0
  • Input Voltage
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.6.1.992.0
  • Output Voltage
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.7.1.992.0
  • Input Current
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.8.1.992.0
  • Output Current
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.9.1.992.0

Power Module B

  • State
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.4.1.993.0
  • Failure Reason
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.5.1.993.0
  • Input Voltage
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.6.1.993.0
  • Output Voltage
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.7.1.993.0
  • Input Current
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.8.1.993.0
  • Output Current
    OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.9.1.993.0

Fan Status

Private MIB / OID

Fan 1

  • State (RPM)
    OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.1
  • Speed (RPM)
    OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.1

Fan 2

  • State
    OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.2
  • Speed (RPM)
    OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.2

Fan 3

  • State
    OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.3
  • Speed (RPM)
    OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.3

Routing Table Information (Summary)

  • Number of active routes
  • Number of OSPF / BGP neighbors

Currently Not Available
Please share the OIDs being used in the EMS for other devices in the network.


Session Information (NAT)

  • Number of active NAT sessions

Additional details required.
Please share the OIDs currently used in the EMS for other devices.


SLA Monitoring Parameters

Additional details required.
Please share the OIDs currently used in the EMS for other devices.

  • End-to-End Latency (e.g., ICMP RTT)
  • Jitter
  • Packet Loss
  • SLA Operation Status (Active / Failed)
  • SLA Threshold Breach Status