231 lines
5.1 KiB
Markdown
231 lines
5.1 KiB
Markdown
# Nivetti NiOS MIBs
|
|
|
|
The following minimum parameters are required to be discovered to retrieve data using SNMP from Nivetti make Routers, in order to monitor them through a Network Management System (NMS).
|
|
|
|
---
|
|
|
|
## Required Minimum Parameters for SNMP Discovery
|
|
|
|
Standard SYSTEM-MIB is supported
|
|
(Details to be configured in System PG)
|
|
|
|
### System Information
|
|
|
|
1. System Name
|
|
2. System Description
|
|
3. System Uptime
|
|
4. System Contact
|
|
5. System Location
|
|
|
|
---
|
|
|
|
## CPU Utilization
|
|
|
|
1. Current CPU Utilization
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.1.1.5.1.3.0.1
|
|
CPU usage is displayed in tenths of a percent unit.
|
|
To get absolute percentage, divide the fetched value by 10.
|
|
|
|
2. Average CPU Utilization (1 min / 5 min / 15 min)
|
|
Currently Not Available
|
|
|
|
3. Per-Core Utilization
|
|
Per-core utilization is not applicable for this device
|
|
|
|
---
|
|
|
|
## Memory Utilization
|
|
|
|
### RAM
|
|
|
|
- Total Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.1
|
|
- Used Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.1
|
|
- Free Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.1
|
|
- Memory Utilization (%)
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.1
|
|
|
|
---
|
|
|
|
### Internal Storage (Flash)
|
|
|
|
- Total Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.2
|
|
- Used Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.2
|
|
- Free Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.2
|
|
- Memory Utilization (%)
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.2
|
|
|
|
---
|
|
|
|
### User Storage (Flash)
|
|
|
|
- Total Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.6.1.3.0.3
|
|
- Used Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.8.1.3.0.3
|
|
- Free Memory
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.7.1.3.0.3
|
|
- Memory Utilization (%)
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.2.1.9.1.3.0.3
|
|
|
|
---
|
|
|
|
## Interface Statistics
|
|
|
|
Standard IF-MIB is supported for both physical and virtual interfaces.
|
|
|
|
- Interface Name / Description
|
|
- Interface Type (Ethernet, Serial, Loopback, etc.)
|
|
- Interface Duplex Status
|
|
- Interface Status (Up / Down)
|
|
- Operational Status (Up / Down)
|
|
- Administrative Status (Up / Down)
|
|
- Interface IP Address
|
|
- Interface Subnet Mask
|
|
- Interface Index
|
|
- Interface Speed
|
|
- Inbound Octets
|
|
- Outbound Octets
|
|
- Inbound Unicast Packets
|
|
- Outbound Unicast Packets
|
|
- Inbound Discards
|
|
- Outbound Discards
|
|
- Inbound Errors
|
|
- Outbound Errors
|
|
- Input Queue Length
|
|
- Output Queue Length
|
|
|
|
---
|
|
|
|
## Temperature Sensors
|
|
|
|
Private MIB / OID
|
|
|
|
### Current Temperature Readings
|
|
|
|
- Air Inlet Temperature
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.1
|
|
- Air Outlet Temperature
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.2
|
|
- CPU Temperature
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.5.1.3.0.3
|
|
|
|
### Low Tolerance Thresholds
|
|
|
|
- Low Air Inlet Tolerance
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.1
|
|
- Low Air Outlet Tolerance
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.2
|
|
- Low CPU Tolerance
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.6.1.3.0.3
|
|
|
|
### High Tolerance Thresholds
|
|
|
|
- High Air Inlet Tolerance
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.1
|
|
- High Air Outlet Tolerance
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.2
|
|
- High CPU Tolerance
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.3.1.7.1.3.0.3
|
|
|
|
---
|
|
|
|
## Power Supply Status
|
|
|
|
Use: NIOS-CHASSIS-MIB
|
|
Displayed only when the power module is ON
|
|
|
|
### Power Module A
|
|
|
|
- State
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.4.1.992.0
|
|
- Failure Reason
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.5.1.992.0
|
|
- Input Voltage
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.6.1.992.0
|
|
- Output Voltage
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.7.1.992.0
|
|
- Input Current
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.8.1.992.0
|
|
- Output Current
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.9.1.992.0
|
|
|
|
### Power Module B
|
|
|
|
- State
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.4.1.993.0
|
|
- Failure Reason
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.5.1.993.0
|
|
- Input Voltage
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.6.1.993.0
|
|
- Output Voltage
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.7.1.993.0
|
|
- Input Current
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.8.1.993.0
|
|
- Output Current
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.6.1.9.1.993.0
|
|
|
|
---
|
|
|
|
## Fan Status
|
|
|
|
Private MIB / OID
|
|
|
|
### Fan 1
|
|
|
|
- State (RPM)
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.1
|
|
- Speed (RPM)
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.1
|
|
|
|
### Fan 2
|
|
|
|
- State
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.2
|
|
- Speed (RPM)
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.2
|
|
|
|
### Fan 3
|
|
|
|
- State
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.5.1.255.0.3
|
|
- Speed (RPM)
|
|
OID: .1.3.6.1.4.1.46634.1.2.5.1.5.1.6.1.255.0.3
|
|
|
|
---
|
|
|
|
## Routing Table Information (Summary)
|
|
|
|
- Number of active routes
|
|
- Number of OSPF / BGP neighbors
|
|
|
|
Currently Not Available
|
|
Please share the OIDs being used in the EMS for other devices in the network.
|
|
|
|
---
|
|
|
|
## Session Information (NAT)
|
|
|
|
- Number of active NAT sessions
|
|
|
|
Additional details required.
|
|
Please share the OIDs currently used in the EMS for other devices.
|
|
|
|
---
|
|
|
|
## SLA Monitoring Parameters
|
|
|
|
Additional details required.
|
|
Please share the OIDs currently used in the EMS for other devices.
|
|
|
|
- End-to-End Latency (e.g., ICMP RTT)
|
|
- Jitter
|
|
- Packet Loss
|
|
- SLA Operation Status (Active / Failed)
|
|
- SLA Threshold Breach Status
|